Part N of the National Building Regulations (SANS 10400-N, Glazing) exists because people walk into glass, especially in doors, low windows and bathrooms. Safety glass either crumbles into small blunt pieces (toughened) or stays held together by its interlayer (laminated) when it breaks. This checker applies the main rules to a single pane.
Where safety glass is required
| Location | Rule |
|---|---|
| Doors | Safety glass for any pane over 1 m². A pane of 1 m² or less may be ordinary glass at least 6 mm thick. |
| Low-level glazing | Glass less than 800 mm above the floor must be safety glass, or at least 6 mm ordinary glass if the pane is no bigger than 1 m². |
| Window sills | Unless there is a barrier, sills should be at least 300 mm above the floor. |
| Showers and baths | Always safety glass. |
| Shopfronts | Safety glass for shop windows and shopfronts over 1 m². |
| Stairs, ramps and landings | Safety glass where glass is less than 1.8 m above the pitch line or landing. |
In practice, almost every glazed aluminium door panel is bigger than 1 m², so sliding, stacking, folding and French doors are made with safety glass as standard.
Ordinary glass thickness by area
Where safety glass is not required, clear annealed float glass is chosen by the area of the pane:
| Pane area | Minimum thickness |
|---|---|
| Up to 0.75 m² | 3 mm |
| 0.75 – 1.5 m² | 4 mm |
| 1.5 – 2.1 m² | 5 mm |
| 2.1 – 3.2 m² | 6 mm |
Exposure to wind, the height of the building and the way the glass is supported all affect the final thickness, so your glazier may specify thicker glass than this.
Toughened or laminated?
Toughened glass is heat-treated, about four to five times stronger than ordinary glass, and breaks into small granules. It can't be cut after toughening, so it is made to size. Laminated glass (6.38 mm is the usual door glass) is two sheets bonded with a plastic interlayer. It cracks but stays in the frame, which also makes it harder to break through and cuts out most UV. Many installers use laminated glass in doors for security and toughened in showers and frameless doors. Read more on our aluminium door glass page.
Marking and compliance
Safety glass should carry a permanent mark showing it meets the relevant South African standard. Large clear panes that people might not see, such as full-height glass doors and shopfronts, should also be made visible with a manifestation such as etched bands or decals. If your plans are being submitted to council, your architect or the glazier can provide the glazing specification. When you request a quote, ask for the glass type and thickness to be written on it.
Frequently asked questions
Does an aluminium sliding door need safety glass?
Is 6.38 mm laminated glass safety glass?
Do windows need safety glass?
Who is responsible for using the right glass?
More aluminium door tools
| Mark | Drawing | Tool | What it does | |
|---|---|---|---|---|
| T01 | Door Panel Layout Calculator | Panel count, panel width and clear opening for sliding, stacking, folding and French doors, drawn to scale. | Open | |
| T02 | Opening Measuring Calculator | Turn three widths, three heights and two diagonals into an order size, and check the opening is square. | Open | |
| T03 | Glass Weight and Roller Calculator | Weight of a glass door panel by size and glass type, and the roller rating it needs. | Open | |
| T05 | Door and Window Schedule Builder | List every opening with size, type, colour and glass, then print it or send it as one quote request. | Open |